Product Details
Brand Name: Wilo
Model Number: Wilo CronoLine IL-E
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: negotiable
Packaging Details: Wooden Chest
Payment Terms: L/C,D/A,D/P,MoneyGram,Western Union,T/T
Supply Ability: 100
Maximum Lift: |
80m |
Maximum Discharge: |
550m³/H |
Driver Type: |
CNC |
Number Of Operating Impeller: |
Single Stage Pump |
Working Pressure: |
13bar/16bar |
Impeller Feeding Mode: |
Single Suction Pump |
Pump Shaft Position: |
Vertical Pump |
Pump Case Bonding: |
Verticaljoint Surface |
Installation Height: |
Self-irrigating Centrifugal Pump |
Impeller Structure: |
Closed |
Specification: |
Series Structure |
Temperature Range During Storage: |
-20 °c To +60 °c |
Temperature Range During Operation: |
0 °c To +40 °c |
Fluid Temperature: |
-20 °c To +140 °c |
Protection Grade: |
IP55 |
Maximum Lift: |
80m |
Maximum Discharge: |
550m³/H |
Driver Type: |
CNC |
Number Of Operating Impeller: |
Single Stage Pump |
Working Pressure: |
13bar/16bar |
Impeller Feeding Mode: |
Single Suction Pump |
Pump Shaft Position: |
Vertical Pump |
Pump Case Bonding: |
Verticaljoint Surface |
Installation Height: |
Self-irrigating Centrifugal Pump |
Impeller Structure: |
Closed |
Specification: |
Series Structure |
Temperature Range During Storage: |
-20 °c To +60 °c |
Temperature Range During Operation: |
0 °c To +40 °c |
Fluid Temperature: |
-20 °c To +140 °c |
Protection Grade: |
IP55 |
Product Description
Wilo-CronoLine-IL-E adopts an integrated electronic power regulation device, which can save energy and is a professional device that complies with the EN 61000-3-2 standard. Flow range : <550m³/h Lift range : ≤80m Max.operating pressure at different fluid temperature : 13bar/16bar Temperature range : -20ºC~+140ºC Nominal diameter :DN 40 to DN 200 Aplication field :The CronoLine-IL-E series is mainly suitable for hot water heating systems, cooling water and cold water circulation circuits, industrial circulation systems, heat transfer circulation circuits, and irrigation systems |
![]() |
Your advantages
Energy savings due to integrated electronic power adjustment
Optional interfaces for bus communication using plug-in IF-Modules
Simple operation with Green Button Technology and display
Integrated dual pump management
Integrated full motor protection (PTC thermistor sensor) with trip electronics
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID-Control
Constant speed (n=constant)
Manual operation level
Green button and display
Differential pressure setpoint setting
Setting the speed (manual control mode)
Setting the operating mode
Setting the pump ON/OFF
Configuration of all operating parameters
Fault acknowledgement
External control functions
"Overriding Off" control input
"External pump cycling" control input (only effective in twin-head pump operation)
Analogue input 0 - 10 V, 0 - 20 mA for constant speed (DDC) and remote setpoint adjustment
Analogue input 2 - 10 V, 4 - 20 mA for constant speed (DDC) and remote setpoint adjustment
Analogue input 0 - 10 V for actual value signal from pressure sensor
Analogue input 2 - 10 V, 0 - 20 mA, 4 - 20 mA for actual value signal from pressure sensor
Signal and display functions
Collective fault signal SSM
Collective run signal SBM
Data exchange
Infrared interface for wireless data exchange with IR-Stick
Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated trip electronics
Access disable
Dual pump management (twin-head pump or 2 x single pumps)
Main/standby operation (automatic fault-actuated switchover)
Pump cycling main/standby operation after 24 hours
Parallel operation
Parallel operation (efficiency-optimised peak-load activation and deactivation)
Typekey
Example | IL-E 50/190-11/2-R1 |
IL-E | In-line pump with electronic control |
50 | Nominal diameter DN of the pipe connection |
190 | Nominal impeller diameter |
11 | Rated power P2 in kW |
2 | Number of poles |
R1 | Version without pressure sensor |
Technical data
Permissible temperature range of -20 °C to +140 °C
Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
Mains connection
3~440 V ±10 %, 50/60 Hz
3~400 V ±10%, 50/60 Hz
3~380 V -5% +10%, 50/60 Hz
Compliance with electromagnetic compatibility without additional measures:
Interference emission for residential environment according to EN 61800-3:2018
Interference immunity for industrial environments according to EN 61800-3:2018
Protection class IP55
Nominal diameter DN 40 to DN 200
Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
Materials
Pump housing and lantern: EN-GJL-250
Impeller
Standard version: EN-GJL-200
Special version: Bronze CuSn 10
Special version: Stainless steel 1.4408
Shaft: 1.4122
Mechanical seal: AQEGG; other mechanical seals on request
Construction
Single-stage, low-pressure centrifugal pump in in-line design with
Mechanical seal
Flange connection
Lantern
Coupling
Drive with integrated electronic speed control